Guide

AS 5488 quality levels explained: QL-A, QL-B, QL-C and QL-D

AS 5488 grades subsurface utility information from QL-D to QL-A. What each level means, the tolerances that apply, and which one your project actually needs.

In short

AS 5488 is the Australian Standard for classifying subsurface utility information. It grades how reliable the information is across four levels, from QL-D (records only) to QL-A (exposed and measured). QL-B, the usual result of on-site locating, carries a tolerance of ±300 mm horizontally and ±500 mm vertically. QL-A carries ±50 mm.

The four levels

From records to proof

QL-D: Plans and records

No tolerance set

Existing records such as Before You Dig plans, with no checks on site.

Early planning only. It tells you a service may exist, not where it is.

Your Before You Dig enquiry

QL-C: Surface features

±300 mm horizontal / No vertical tolerance

Records correlated with what’s visible on site, such as pits, valves and meters.

Initial route planning. The path between surface features is still an estimate.

Site survey

QL-B: Located on site

±300 mm horizontal / ±500 mm vertical

Detected on site with electromagnetic locating and GPR.

Design development and marking out before you dig. This is where locating work typically sits.

What we typically deliver

QL-A: Exposed and proven

±50 mm horizontal / ±50 mm vertical

The service is physically exposed, usually by vacuum excavation, then measured.

Critical crossings and high-consequence services, where you need certainty.

Requires potholing: ask us

Plan view: horizontal±300 mmSection: depth±500 mm

What AS 5488 is for

AS 5488 gives engineers, surveyors and contractors one shared language for how far to trust a line on a drawing. It doesn’t tell you where a service is. It tells you how confident you can be about that information.

It’s a voluntary standard rather than legislation, but it’s commonly written into project specifications and contracts. Check your own specification for which level it calls for.

Which level do you need?

Most projects mix levels. It’s common to use QL-D early on, move to QL-B across the work area, and then prove the critical crossings at QL-A.

A good question to ask is what would happen if the information were wrong. A garden bed and a trench beside a high-pressure gas main don’t need the same answer.

Where we fit in

Electromagnetic locating and GPR typically produce QL-B information, and that’s what we’re set up to deliver. QL-A needs the service to be physically exposed, usually by vacuum excavation. If your project needs potholing, tell us when you ask for a quote and we’ll talk through how to organise it.

One honest caveat: no method finds everything, and GPR in particular has no set tolerance on its own. A good report records what was checked, how it was checked and what couldn’t be confirmed.

FAQs

Questions, answered

It’s a voluntary Australian Standard rather than legislation, but it often becomes mandatory through project specifications and contracts.

±300 mm horizontally and ±500 mm vertically.

QL-B is detected from the surface, usually with electromagnetic locating and GPR. QL-A means the service has been physically exposed and measured, with a tolerance of ±50 mm.

Plans on their own generally sit at QL-D: useful records, but not verified on site.

Get in touch

Have a question about your site?

Tell us what you’re digging and where. Jason will come back to you with the right method and a clear quote, obligation free.

Request a site inspection